Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
J. appl. oral sci ; 19(4): 301-305, July-Aug. 2011. ilus
Article in English | LILACS | ID: lil-599753

ABSTRACT

Titanium reacts strongly with elements, mainly oxygen at high temperature. The high temperature of titanium laser welding modifies the surface, and may interfere on the metal-ceramic tensile bond strength. OBJECTIVE: The influence of laser welding on the titanium-ceramic bonding has not yet been established. The purpose of this in vitro study was to analyze the influence of laser welding applied to commercially pure titanium (CpTi) substructure on the bond strength of commercial ceramic. The influence of airborne particle abrasion (Al2O3) conditions was also studied. MATERIAL AND METHODS: Forty CpTi cylindrical rods (3 mm x 60 mm) were cast and divided into 2 groups: with laser welding (L) and without laser welding (WL). Each group was divided in 4 subgroups, according to the size of the particles used in airborne particle abrasion: A - Al2O3 (250 µm); B - Al2O3 (180 µm); C - Al2O3 (110 µm); D - Al2O3 (50 µm). Ceramic rings were fused around the CpTi rods. Specimens were invested and their tensile strength was measured at fracture with a universal testing machine at a crosshead speed of 2.0 mm/min and 200 kgf load cell. Statistical analysis was carried out with analysis of variance and compared using the independent t test (p<0.05). RESULTS: Significant differences were found among all subgroups (p<0.05). The highest and the lowest bond strength means were recorded in subgroups WLC (52.62 MPa) and LD (24.02 MPa), respectively. CONCLUSION: Airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Mechanical retention decreased in the laser-welded specimens, i.e. the metal-ceramic tensile bond strength was lower.


Subject(s)
Air Abrasion, Dental/methods , Ceramics/chemistry , Dental Bonding/methods , Dental Soldering/methods , Lasers , Titanium/chemistry , Analysis of Variance , Materials Testing , Microscopy, Electron, Scanning , Metal Ceramic Alloys/chemistry , Particle Size , Surface Properties , Tensile Strength
2.
Braz. dent. j ; 20(5): 403-409, 2009. tab, ilus
Article in English | LILACS | ID: lil-537547

ABSTRACT

The aim of this study was to analyze the shear bond strength between commercially pure titanium, with and without laser welding, after airbone-particle abrasion (Al2O3) and 2 indirect composites. Sixty-four specimens were cast and divided into 2 groups with and without laser welding. Each group was divided in 4 subgroups, related to Al2O3 grain size: A - 250 µm; B - 180 µm; C- 110 µm; and D - 50 µm. Composite rings were formed around the rods and light polymerized using UniXS unit. Specimens were invested and their shear bond strength at failure was measured with a universal testing machine at a crosshead speed of 2.0 mm/min. Statistical analysis was carried out with ANOVA and Tukey's test (á=0.05). The highest bond strength means were recorded in 250 µm group without laser welding. The lowest shear bond strength means were recorded in 50 µm group with laser welding. Statistically significant differences (p<0.05) were found between all groups. In conclusion, airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Shear bond strength decreased in the laser welded specimens.


O objetivo deste estudo foi analisar a força de união entre o titânio comercialmente puro com solda e sem solda modificado por partículas de óxido de alumínio (Al2O3) e duas resinas indiretas. Um total de 64 espécimes foram fundidas e divididas em dois grupos sem solda e com solda a laser. Cada grupo foi novamente divididos em 4 subgrupos, de acordo com o tamanho de partículas de óxido de alumínio utilizado: A - Al2O3 (250 µm); B - Al2O3 (180 µm); C- Al2O3 (110 µm); D - Al2O3 (50 µm). Anéis de resina foram polimerizados ao redor das hastes de titânio no equipamento UniXS. Os espécimes foram embutidos em gesso e a força de união foi mensurada com auxílio da máquina de ensaios universais. ANOVA e teste de Tukey (p<0,05) foram utilizados para análise estatística. Os maiores valores de força de união foram registrados no grupo de 250 µm sem solda a laser. Os menores valores foram registrados para o grupo de 50 µm com solda a laser. Alterações estatisticamente significantes foram observadas entre todos os grupos (p<0,05). As forças de união diminuíram significantemente com a diminuição dos tamanhos das partículas de óxido de alumínio. A força de união diminuiu nas amostras que receberam a solda a laser.


Subject(s)
Composite Resins , Dental Alloys , Dental Soldering/methods , Light-Curing of Dental Adhesives , Titanium , Air Abrasion, Dental , Analysis of Variance , Dental Stress Analysis , Lasers , Materials Testing , Particle Size , Shear Strength , Statistics, Nonparametric , Welding/methods
3.
Braz. dent. j ; 16(2): 140-144, maio-ago. 2005. ilus, graf
Article in English | LILACS | ID: lil-413414

ABSTRACT

Cinco combinações de materiais comumente utilizados para registros intermaxilares em casos de extremidades livres bilaterais foram avaliados: base de resina acrílica + cera; base de resina acrílica + pasta zincoenólica; base de resina acrílica + cera + resina Duralay; silicona de condensação; e placa de resina acrílica + hidrocolóide irreversível. Foi realizada a medida da distância vertical entre pontos referenciais em 6 regiões nas bases dos modelos articulados. As medidas obtidas com a articulação manual dos modelos foram tomadas como padrão de comparação para as medidas obtidas com os materiais testados. Os resultados foram submetidos à análise estatística por meio de análise de variância e teste de Tukey. Houve diferença estatisticamente significante (p<0.05) entre a silicona de condensação e a combinação da base de resina acrílica + cera, porém entre os demais materiais não houve diferença estatisticamente significante. A silicona de condensação apresentou as maiores diferenças em relação às medidas obtidas pela articulação manual dos modelos e a combinação da base de resina acrílica + cera apresentou as menores diferenças. Com base nos achados deste estudo, a seguinte escala de reprodutibilidade pode ser estabelecida, do melhor para o pior: base de resina acrílica + cera; placa de resina acrílica + hidrocolóide irreversível; base de resina acrílica + cera + pasta zincoenólica; base de resina acrílica + cera + resina Duralay; e silicona de condensação.


Subject(s)
Humans , Dental Materials , Denture Design , Denture, Partial , Jaw Relation Record/methods , Acrylic Resins/chemistry , Alginates/chemistry , Colloids/chemistry , Dental Articulators , Dental Materials/chemistry , Denture, Partial/classification , Inlay Casting Wax/chemistry , Methylmethacrylates/chemistry , Surface Properties , Silicone Elastomers/chemistry , Vertical Dimension , Zinc Oxide-Eugenol Cement/chemistry
4.
Braz. dent. j ; 11(1): 41-47, jan.-jun. 2000. ilus, CD-ROM
Article in English | LILACS, BBO | ID: biblio-850341

ABSTRACT

Quatro técnicas de registro interoclusal da posição de relação cêntrica fundamentadas em materiais ou combinações de materiais comumente utilizados, foram avaliadas por meio da montagem de modelos de um paciente com desdentamento parcial inferior, sem extremidade livre. Para assegurar a posição correta da relação cêntrica foi utilizado o jig de Lucia. As seguintes condições para o registro do segmento posterior foram avaliadas: registros com cera, cera mais pasta zincoenólica, cera mais resina acrílica Duralay e silicona de condensação (pesada). A avaliação foi realizada pela medida da distância vertical entre pontos referenciais nas bases dos modelos e cálculo das variações ocorridas com cada material. As combinações de cera mais pasta zincoenólica e cera mais resina acrílica Duralay apresentaram menores variações na posição de relação cêntrica


Subject(s)
Humans , Chemistry , Methods
SELECTION OF CITATIONS
SEARCH DETAIL